China Safety Science Journal ›› 2021, Vol. 31 ›› Issue (7): 157-163.doi: 10.16265/j.cnki.issn 1003-3033.2021.07.022

• Public safety • Previous Articles     Next Articles

Study on influence of air curtain on temperature and flow field of subway tunnel fires

TAO Liangliang1, ZENG Yanhua1, LIU Zhenhan1, PENG Junqin1, ZHOU Xiaohan2   

  1. 1 Key Laboratory of Transportation Tunnel Engineering, Ministry of Education, Southwest Jiaotong University, Chengdu Sichuan 610031, China;
    2 School of Civil Engineering, Chongqing University, Chongqing 400045, China
  • Received:2021-04-03 Revised:2021-06-18 Online:2021-07-28 Published:2022-01-28

Abstract: In order to explore influence of air curtain on temperature and flow field distribution in subway tunnel, longitudinal temperature, maximum temperature of vault and flow field distribution in tunnel under different HRR(heat release rates) of fire source, air curtain jet velocities and angles were studied by FDS (Fire Dynamics Simulator). The results show that jet velocity of air curtain should be at least 16, 18 and 20 m/s to ensure smoke control effect when HRR is 10, 15 and 20 MW. Increasing jet angle, in cases where it is smaller than 45°, can accelerate temperature attenuation of vault, but such effect will be little as it is more than 45°. Maximum temperature of vault decreases along with increase of jet velocity, but increases with that of jet angle which changes temperature distribution in tunnel by influencing vortex between fire source and air curtain.

Key words: tunnel fire, air curtain, temperature distribution, maximum temperature of vault, flow field

CLC Number: