中国安全科学学报 ›› 2017, Vol. 27 ›› Issue (12): 32-36.doi: 10.16265/j.cnki.issn1003-3033.2017.12.006

• 安全工程技术科学 • 上一篇    下一篇

不同洪水冲击角度下卧式储罐失效问题研究

陈文瑛1 副教授, 杜艳洋1, 马峻1 教授, 魏利军2 教授级高工   

  1. 1首都经济贸易大学 安全与环境工程学院,北京 100071
    2中国安全生产科学研究院 危险化学品安全技术研究所,北京 100012
  • 收稿日期:2017-09-05 修回日期:2017-11-19 出版日期:2017-12-28 发布日期:2020-10-10
  • 作者简介:陈文瑛 (1975—),女,内蒙古包头人,博士,副教授,主要从事系统安全分析与评价方面的研究。E-mail:chenwy@cueb.edu.cn。杜艳洋 (1991—),男,湖北襄阳人,硕士研究生,研究方向为化工安全、安全系统工程。E-mail:13522767679@163.com。
  • 基金资助:
    科技部国家重点研发计划(2016YFC0801501); 2017年首都经济贸易大学中青年教师科研能力提升项目(00891762791111)。

Study on failure of horizontal storage tank impacted by flood from different angles

CHEN Wenying1, DU Yanyang1, MA Jun1, WEI Lijun2   

  1. 1School of Safety and Environmental Engineering, Capital University of Economics and Business, Beijing 100071, China
    2Institute for Hazardous Chemicals Safety Technology, China Academy of Safety Science and Technology, Beijing 100012, China
  • Received:2017-09-05 Revised:2017-11-19 Online:2017-12-28 Published:2020-10-10

摘要: 为预防洪水灾害作用下化工园区卧式储罐失效事故,通过理论推导和实证分析,研究不同洪水冲击角度下卧式储罐的失效问题。首先,建立洪水侧向冲击角度下卧式储罐的受力模型;然后,定义洪水侧向冲击角度下卧式储罐易损系数和受冲击的衰减系数;最后,基于受力模型和衰减系数,分析不同洪水冲击角度下储罐型号、装量水平对卧式储罐失效的影响。结果表明:当洪水冲击角度θ从0变到π时,储罐受洪水冲击作用力的衰减系数先增后减,当公式时为最大;卧式储罐尺寸越大,螺栓受到的冲击作用力越大,储罐越容易失效;卧式储罐装量水平越高,螺栓受到的冲击作用力越小,储罐越安全。

关键词: 洪水, 冲击角度, 卧式储罐, 易损系数, 衰减系数

Abstract: For the sake of preventing horizontal storage tank failure accidents resulting from flood impact in chemical industry parks, theoretical derivation and empirical analysis were carried out to discuss failure of horizontal storage tank impacted by flood from different angles. Firstly, horizontal storage tank failure analysis was accomplished considering flood impacting on the tank with a certain degree, then vulnerability coefficient and attenuation coefficient were defined. Finally, effects of different parameters including tank type, tank level influencing on horizontal storage tank failure under different flood impact angle were analyzed. The results show impact attenuation coefficient increases at first and then decreases when the impact angle θ varies from 0 to π, also, rises to the maximum when θ is π2, that the larger the tank is, the greater the force on the bolts will be, thus the tank will be more likely to fail, and that the higher the storage level is, the smaller the force on the bolts will be, and the safer the tank will be.

Key words: flood, impact angle, horizontal cylindrical vessel, vulnerability coefficient , attenuation coefficient