China Safety Science Journal ›› 2019, Vol. 29 ›› Issue (1): 55-61.doi: 10.16265/j.cnki.issn1003-3033.2019.01.010

• Safety Science of Engineering and Technology • Previous Articles     Next Articles

Study on movement characteristics of dust raised by weak shock wave in horizontal pipeline

ZHANG Xiaoliang, YE Shengjun, LIU Xiaochen, LI Hao, YANG Luying   

  1. College of Urban Construction and Safety Engineering, Shanghai Institute of Technology, Shanghai 201418, China
  • Received:2018-10-10 Revised:2018-12-15 Online:2019-01-28 Published:2020-11-23

Abstract: In view of that in the mechanical processing industry, the deposited dust in the horizontal pipeline often cause huge losses to people's lives and property through explosion resulting from the dust raised secondarily, movement characteristics of dust raised in horizontal pipeline were studied experimentally by using common aluminum alloy dust as the research object, a self-designed horizontal pipeline as the test platform, and a PIV system and other equipment as the means of data acquisition. The results show that under the action of thin membrane and weak shock wave, the maximum velocity of dust increases first, then decreases and then increases with the increase of deposition, that under the action of no membrane and weak shock wave, the maximum velocity of dust decreases first and then increases with the increase of deposition, that membrane makes the maximum velocity of raised dust decrease, and that under the action of weak shock wave, the membrane can reduce the maximum velocity of secondary dust and change the flow field of dust cloud.

Key words: dust, dust removal pipe, weak shock wave, diaphragm, particle image velocimetry(PIV) testing system

CLC Number: