中国安全科学学报 ›› 2019, Vol. 29 ›› Issue (7): 123-128.doi: 10.16265/j.cnki.issn1003-3033.2019.07.020

• 安全卫生工程技术 • 上一篇    下一篇

气动涡旋雾幕性能影响因素试验及优化研究

陈景序1,2, 荆德吉**1,2 副教授, 葛少成3 教授   

  1. 1 辽宁工程技术大学 安全科学与工程学院,辽宁 阜新 123000;
    2 矿山热动力灾害与防治教育部 重点实验室,辽宁 阜新 123000;
    3 太原理工大学 安全与应急管理工程学院,山西 太原 030024
  • 收稿日期:2019-03-26 修回日期:2019-05-16 出版日期:2019-07-28 发布日期:2020-10-21
  • 通讯作者: ** 荆德吉(1984—),男,辽宁抚顺人,博士,副教授,主要从事安全工程专业粉尘综合治理技术的教学与科研工作。E-mail: jingdeji@sina.com。
  • 作者简介:陈景序 (1989—),男,辽宁鞍山人,博士,研究方向为粉尘综合治理技术。E-mail:chanjingxu@sina.com。
  • 基金资助:
    国家自然科学基金资助(51274116);国家自然科学基金青年基金资助(51704146)。

Experimental study on factors influencing performance of pneumatic vortex spray curtain and its optimization

CHEN Jingxu1,2, JING Deji1,2, GE Shaocheng3   

  1. 1 College of Safety Science and Engineering, Liaoning Technical University, Fuxin Liaoning 123000, China;
    2 Key Laboratory of Mine Thermodynamic Disaster and Control of Ministry of Education, Fuxin Liaoning 123000, China;
    3 College of Safety and Emergency Management Engineering, Taiyuan University of Technical, Taiyuan Shanxi 030024, China
  • Received:2019-03-26 Revised:2019-05-16 Online:2019-07-28 Published:2020-10-21

摘要: 为了掌握气动涡旋雾幕发生装置的雾化性能,依据气动涡旋雾幕形成机制架设相似试验平台,并围绕主要影响因素设计多因素正交试验,采用多因素回归分析法获得雾化半径预测模型,并对该装置的除尘效果进行试验验证。结果表明:射流风速与雾化半径的关系为正相关且影响较大,工作夹角和雾化压力为负相关;正交试验分析结果显示,对雾化半径的影响从大到小依次为射流风速、工作夹角、雾化压力。除尘效果试验检验结果证明:该装置所形成的旋转雾幕可将前端高浓度粉尘隔绝在雾幕之前,全尘和呼吸性粉尘降尘效率分别为93.03%、87.75%,对扩散的粉尘捕集效果较为显著。

关键词: 气动涡旋雾幕, 参数优化, 雾化半径, 射流风速, 工作夹角, 除尘效果

Abstract: In order to learn about the atomization performance of the pneumatic vortex spray curtain device, a similar experimental platform was set up according to the formation mechanism. Multi-factor orthogonal tests were designed considering main influencing factors and the atomization performance prediction model was obtained by multi-factor regression analysis. Experiments were carried out to verify the dust removal effect of the device. The results show that the jet wind speed is positively correlated with the atomization radius and it has great influence on the radius, that the spray working angle and the atomization pressure are negatively correlated, and that the squence of factors affecting atomization radius from big to small is the jet wind speed, the spray working angle and the atomization pressure. The dust removal effect experimental results prove that the pneumatic vortex spray curtain can isolate the high concentration dust, that the removing efficiencies of dust and respirable dust are 93.03% and 87.75% respectively, and that the effect on dust collection is more significant.

Key words: pneumatic vortex spray curtain, parameter optimization, atomization radius, jet wind speed, working angle, dedusting effect

中图分类号: