中国安全科学学报 ›› 2021, Vol. 31 ›› Issue (3): 121-127.doi: 10.16265/j.cnki.issn1003-3033.2021.03.017

• 公共安全 • 上一篇    下一篇

不同温度下超高层建筑窗口火蔓延模拟分析

王宇 副教授, 邢佳, 周盈彤   

  1. 沈阳建筑大学 土木工程学院,辽宁 沈阳 110168
  • 收稿日期:2020-12-13 修回日期:2021-02-19 出版日期:2021-03-28
  • 作者简介:王 宇 (1977—),男,河北抚宁人,硕士,副教授,主要从事高层建筑抗火、结构抗震等研究。E-mail: wyasyn@163.com。
  • 基金资助:
    辽宁省自然科学基金资助(2019-ZD-0299);国家重点研发计划课题(2018YFC1504303)。

Simulation analysis of window fire spread in super high-rise building at different temperatures

WANG Yu, XING Jia, ZHOU Yingtong   

  1. School of Civil Engineering, Shenyang Jianzhu University,Shenyang Liaoning 110168,China
  • Received:2020-12-13 Revised:2021-02-19 Published:2021-03-28

摘要: 为揭示不同温度条件对凹型超高层建筑窗口羽流火焰融合高度的影响,采用火灾动态仿真模拟软件PyroSim,构建不同温度条件下凹型超高层建筑的火灾模型;分析该模型下竖向连续多窗口温度分布等温线及温度曲线。结果表明:在不同室外温度条件下,纵向连续3窗口比2窗口在达到危险温度540 ℃时,火焰融合高度上升4.5~5.9 m;在达到危险温度350 ℃时,火焰高度上升11.0~13.3 m。纵向连续4窗口比3窗口在达到危险温度540 ℃时,火焰融合高度上升3.0~3.4 m;在达到危险温度350 ℃时,火焰高度上升7.8~9.5 m;对于凹型超高层建筑,室内外温差越大,火焰融合高度越高;从纵向连续3窗口开始,火焰融合高度增长趋势下降。

关键词: 超高层建筑, 窗口, 火焰融合, 室内外温差, 危险温度

Abstract: In order to study influence of different temperature conditions on flame fusion height of window plume of concave super high-rise building, fire model of concave super high-rise building under different temperature conditions were numerically simulated by PyroSim software, and temperature distribution isotherm and temperature curve of longitudinal continuous multiple windows were analyzed. The results show that flame height increases by 4.5-5.9 m when dangerous temperature reaches 540 ℃ at 3 windows compared with 2 windows in longitudinal continuous window.When dangerous temperature reached 350 ℃, flame height increased by 11.0-13.3 m. Flame height increases by 3.0-3.4 m when longitudinal continuous 4 window compared with 3 window combustion at dangerous temperature of 540 ℃. When dangerous temperature is 350 ℃, flame height rises by 7.8-9.5 m. For concave super high-rise building, the greater the temperature difference between indoor and outdoor, the higher the flame fusion height. Begin from longitudinal continuous 3 windows, growth trend of flame fusion height decreases.

Key words: super tall buildings, window, flame fusion, indoor and outdoor temperature difference, dangerous temperature

中图分类号: