中国安全科学学报 ›› 2026, Vol. 36 ›› Issue (9): 240-247.doi: 10.16265/j.cnki.issn1003-3033.2026.09.1987

• 公共安全与应急管理 • 上一篇    下一篇

基于融合预测改进自编码的高层建筑电气火灾预警

李闯闯1(), 招嘉怡1, 王白根2, 程坤2, 李彬1, 苏盛1,**()   

  1. 1 长沙理工大学 电气与信息工程学院, 湖南 长沙 410014
    2 国网安徽省电力有限公司 安庆供电公司, 安徽 安庆 246004
  • 收稿日期:2026-04-12 修回日期:2026-07-10 出版日期:2026-10-20
  • 通信作者:
    ** 苏盛(1975—),男,湖南长沙人,博士,教授,主要从事低压用电安全隐患感知方面的研究。E-mail:。
  • 作者简介:

    李闯闯 (1999—),男,河南范县人,博士研究生,主要研究方向为低压用电安全隐患感知。E-mail:。

    王白根 高级工程师;

    程 坤 高级工程师;

    李 彬 讲师

  • 基金资助:
    国家电网总部科技项目(5400-202320578A-3-2-ZN)

Early warning of electrical fires in high-rise buildings based on improved autoencoder with fusion prediction

Li Chuangchuang1(), Zhao Jiayi1, Wang Baigen2, Cheng Kun2, Li Bin1, Su Sheng1,**()   

  1. 1 College of Electrical and Information Engineering, Changsha University of Science and Technology, Changsha Hunan 410014, China
    2 Anqing Power Supply Company, State Grid Anhui Electric Power Co., Ltd., Anqing Anhui 246004, China
  • Received:2026-04-12 Revised:2026-07-10 Published:2026-10-20

摘要:

为解决高层建筑配电系统中配电箱异常状态识别精度不足的问题,提出一种融合预测任务的改进自编码器模型。首先,基于自主研发的多参数监测装置,采集三相电压、电流、剩余电流、中性线电流及设备温度等多维时序数据,并通过最大-最小归一化方法消除量纲差异;其次,在模型构建中,采用双向门控循环单元(BiGRU)捕捉数据的前后向长期依赖关系,结合缩放点积注意力机制(SDA)强化关键时间步信息,并利用卷积层与通道注意力机制提取多特征间的局部关联特征;然后,模型采用对称式编码-解码结构,通过拼接编码与解码阶段的BiGRU隐藏状态,构建“重构-预测”双任务学习框架,精准预测下一时刻电气参数;最后,通过预测误差的评分函数量化序列异常程度。结果表明:模型的均方根误差(RMSE)、平均绝对误差(MAE)和决定系数R2分别为0.000 9、0.017 8和0.731 3;相比XGBoost、GRU和Transformer等模型,MAE和R2指标均表现出较好的预测结果,并对剩余电流渐变漂移、温度异常升高和电流突变扰动等异常特征产生相应的异常评分响应。

关键词: 融合预测, 高层建筑, 自编码器, 电气火灾预警, 双向门控循环单元(BiGRU), 注意力机制

Abstract:

To address the insufficient accuracy of abnormal-state identification in high-rise buildings distribution boxes, an improved autoencoder model with fusion prediction is proposed. First, the data were normalized using the min-max method to eliminate dimensional differences. Second, the model employed a BiGRU to capture temporal dependencies in both forward and backward directions. A scaled dot-product attention (SDA) mechanism was applied to the hidden states of BiGRU to enhance key time-step information Convolutional layers and a channel attention mechanism were also incorporated to extract local correlations among features. Then, a symmetric encoder-decoder structure was adopted, and hidden states from both encoding and decoding phases were concatenated to form a "reconstruction-prediction" dual-task framework, enabling the prediction of electrical parameters for the next time step. Finally, a scoring function based on prediction error was used to quantify sequence anomalies. The results show that root mean square error(RMSE),mean absolute error(MAE), and coefficient of determination R2 are 0.000 9, 0.017 8, and 0.731 3, respectively. Compared with XGBoost, gated recurrent unit(GRU), and Transformer, the model shows improved performance in MAE and R2 and produces corresponding anomaly-score responses to gradual residual-current drift, abnormal temperature rise, and sudden current disturbances.

Key words: fusion prediction, high-rise buildings, autoencoder, electrical fire warning, bidirectional gated recurrent unit (BiGRU), attention mechanism

中图分类号: